Concept sheet 01 · not a client job
Welded bearing mount, machined after weld
- Material
- 316L plate, 12 mm
- Batch basis
- 40 off
- Critical
- Ø40 H7 ⟂ 0.05 to A
- Drawing
- DP-01 rev B
Process route
- 10Laser cut base, upright and gussets from 12 mm 316L, N₂ assist
- 20Turn boss from Ø75 bar, bore left 2 mm under size
- 30Fit-up in a fixture locating the base holes; tack
- 40TIG weld gussets 6 mm fillet both sides, balanced sequence
- 50Mill base flat, then bore Ø40 H7 in the same set-up
- 60Pickle & passivate (finish confirmed with customer)
- 70Inspect, tag, pack
Inspection plan
| Feature | Method | Freq. |
|---|---|---|
| Ø40 H7 | Plug gauge, bore gauge | 100% |
| ⟂ 0.05 to A | Square + indicator | 1 in 5 |
| Flatness 0.05 | Surface plate | 1 in 5 |
| Weld size | Fillet gauge | FAI |
Asked before quoting
- Email asks for 50 off; the title block says 40. Which quantity should we quote?
- Email says 304; the drawing says 316L. Please confirm the grade.
- Finish says "refer purchase order". Is pickle & passivate acceptable?